Faraday's Law, Lenz's Law and Electromagnetic Induction

Faraday's law says that the EMF induced in a coil equals the negative rate of change of the magnetic flux through it: EMF = -N dΦ/dt. A magnet moving through a coil changes the flux, so a voltage appears.

Lenz's law explains the minus sign: the induced current opposes the change that causes it. With the circuit closed the magnet is braked and falls more slowly; with the circuit open it falls freely. The lost potential energy is dissipated as heat in the coil.

Frequently Asked Questions

What is Faraday's law of induction?

The induced EMF in a coil of N turns is EMF = -N dΦ/dt, where Φ is the magnetic flux through one turn. Faster change of flux or more turns gives a larger voltage.

What does Lenz's law say?

The direction of the induced current is such that its own magnetic field opposes the change in flux that produced it. This is why the EMF changes sign when the magnet enters and when it leaves the coil.

Why does a magnet fall more slowly through a closed coil?

The induced current in the closed circuit exerts a force on the magnet that opposes its motion. Energy conservation: the work done against this force becomes heat I²R in the coil and load. With an open circuit there is no current, so there is no braking.